AgileLab is the sole distributor for Sarstedt, German company provider for customer specific automation solutions guaranteeing the maximum flexibility and assisting you to improve your lab process to be more efficient and cost-effective. We have a broad portfolio of compact devices and modular automation for pre- and post analytics for clinical and microbiology laboratories.
I- Pre and Post Analytical Automation
Sarstedt Products:
Tube Labeller – Sample Transportation System Tempus600 – Clinical Laboratory Automation
1-Tube Labeller:
Following the analysis order, the laboratory information system (LIS) software carries out patient- specific automated labelling of tubes before blood sampling. Labelled tubes are issued in a tray, ready to use, ensuring that labels are perfectly adhered and no tubes are missing.
Tabletop
- Provision of patient-specific labelled S-Monovettes or Standard tubes
- One set per patient with additional labels and receipt printing
- No incorrect labelling, no missing tubes
- Perfectly positioned labels which increase efficient process in the laboratory
2- Sample Transportation System – Tempus600
It consists of Sending Module (Tempus600 Vita/or Quantit/or Necto), Receiving Module, optional Connecting Module and Control Unit
Sending Module (Tempus600 Vita): Blood sample tubes are sent immediately one by one to the laboratory in a single tube transport without requiring any further packing.
- Easy and intuitive to use – minimal training is required Compatible with all sample tubes from: Length 80-110 mm, diameter 12-18 mm
- Dimensions: (H x W x D) 157 x 37,5 x 41 cm — occupying little space
- Predictable and improved total turnaround time (ToTAT)
- Handles up to 810 sample tubes per hour
- Installation time is Just 2 weeks for new and existing facilities
- Minimal maintenance
Sending Module (Tempus600 Quantit): Many samples can be dispatched simultaneously without any packaging.
You don’t even have to consider orientation, as Quantit manages that. An optional urgency module can be added allowing you to access the system at any time and manually place urgent samples for immediate processing.
- Multiple inlet for up to 25 samples at a time without any packaging
- Ensures minimal time and actions to load and receive samples.
- Samples are always oriented the right way by the system.
- Incompatible samples automatically will be rejected.
- Meets the demand for sending both high volume and urgent samples
- Capacity to handle up to 1050 sample tubes per hour
- Compatible with all sample tubes from: Length 80-110 mm, diameter 12-18 mm
- Dimensions: H x W x D = 123 x 63 x 49 cm
Sending Module (Tempus600® Necto): High throughput automated solution enables accessioning and transportation over long distances. The system streamlines the entire registering and sorting process.
- Samples can be transferred to up to six different destinations – two local bins and four distant destinations.
- Standard Necto comes with one sending module however, extra sending modules can be customized.
- Processes a wide range of materials such as serum, plasma, whole blood, urine etc.
- Sample are sorted using barcodes, dimensions, tube recognition or as a combination
- Cap colour and tube geometry identification is performed via built-in camera
- Intelligent sample routing into waiting loop if test order is missing
- Compatible with all sample tubes of following dimensions: Length 80-110 mm, diameter 12-18 mm (including cap)
- Cabinet dimensions are approximately (HxWxD) 160x220x76 cm.
- Capacity of bulk compartment app. 600 tubes
- Throughput of up to 1200 tubes/hour
- Ideal connection with any analytical platform
- No pre-sorting or handling of sample tubes are required
- Safe, rapid and continuous operation without errors
Receiving Module (Tempus600 Receiving Tray): Located in the laboratory receiving area. The samples arrive, one by one, and are gently slowed down before reaching the Receiving Tray. From there, they are ready to be picked up by laboratory staff.
- Possible brake module and wiring for soft landing in case of high throughput samples
- Soft inside to reduce landing impact
- Lights up when samples arrive
- Dimensions: (H x W x D) 65 x 28 x 43cm
- Small and wall mounted
- Easy to clean
Tempus600 Connection Module: The sample tubes are delivered from the ward to the laboratory through the dedicated point-to-point system in few seconds. Through the connection module, samples are ready to continue the journey into the bulk loader or sorter. From there, they are automatically transferred onto e.g. a track.
- Compatible with laboratory automation systems, including bulk loaders and sorters you have already installed, or planning to introduce, in the laboratory.
- Automated one-touch handling system for sample tubes – fewer work procedures, no hands on the sample tubes and leading to faster and safer handling.
- In case of high throughput sample transportation over long distances a brake module can be fitted to increase sample throughput.
- Dimensions: (H x W x D) 63 x 38 x 23 cm
- Up to 8 connections
TM002 Control Unit: You can control and monitor your TEMPUS600 equipment from one display. The system is able to monitor up to 44 sending stations simultaneously and the software can be seamlessly updated online.
- Control TM002 remotely with any smartphone, tablet or desktop computer
- Fast, easy and intuitive handling using shortcut icons
- Can be connected with laboratory track systems and sorter
- Dimensions: (H x W x D) 26,5 x 32,2 x 5 cm
3- Clinical Laboratory
It consists of Stand-Alone Solutions (De-Capper, Re-Capper, Sorter and Aliquoter, Archiving) or Combined Solutions.
Decapping DC 1200 : Automated decapping of all tube diameters from 11–16 mm
- Decapping is carried out in the analysis rack – no reloading is required.
- Throughput of up to 1,200 tubes per hour
- Easy operation
- Available for existing linear racks
- Minimizes infection risk and overloading
Recapping RC 1200/ 1200S:Automated recapping for tube diameters of 13–16 mm/13-15 mm
- Minimize evaporation
- Prevent contamination
- Archiving cap fits all tubes
- Automated re-processing (decapping/recapping)
DC/RC 900 Flex: Combines pre- and post-analytics in one compact standalone system, preventing repetitive motion incidents associated with manually removing or inserting caps, thereby protecting human resources.
All tubes of 65 to 100 mm length and 11 to 16 mm diameter are processed in a mixed operation without pre-sorting. Other tube sizes can be accommodated upon request.
- High throughput of up to 900 tubes/hour
- Processes any tube diameter from 11 to 16 mm
- Compatible with most racks or carrier types
- Software can be programmed for online or offline operation
- Opens tubes with push caps, stoppers and screw caps
- Identifies tubes by barcode reader and colour sensor
- Can be customised to sort by tube type, barcode, material (colour), etc.
- Closes tubes with archiving caps
- Retrofitting of decapping or recapping modules is possible
Bulk Loader BL 1200 – Sorting into rack systems or directly to the laboratory line: Revolutionizes sample processing in the clinical laboratory. Load closed specimen tubes into the bulk loader – no sorting or handling are required. Tubes are automatically placed onto the processing track of the Bulk Loader. Then, the sample type is identified via the integral ID module.
Samples can be distributed and sorted into centrifuge adapters, feeder/exit trays for laboratory lines, analyser racks, standard racks, archiving racks or directly to the laboratory line via the SORT CONNECT module.
- Throughput of up to 1,200 tubes per hour
- Up to 600 tubes per sorting platform
- Up to 1,200 tubes for sorting platform
- The SORT CONNECT module connects directly to the laboratory line
- Checks detect and sort out error samples.
Sample distribution system PVS 1625: Full function pre- and post-analytical system
- Modular configuration according to customer needs. It consists of:
- Loading platform and/or Bulk Loader
- ID Module
- Decapper
- Recapper
- Aliquoter
- Sorter
- For all common tube types
- 13–16 mm diameter
- 65–100 mm length
- Compatible with most racks or carrier types
There are two versions of recapper modules for archiving or for sending samples. Tubes are either closed with an archiving cap (all diameters from 13–16 mm) or with a screw cap (Sarstedt tubes with a diameter of 13 or 15 mm).
Barcoded secondary tubes are prepared and the requested volume is dispensed at the Aliquoter. No more sample mix-ups will occur and the available volume will be used in the most efficient way.
II-Laboratory Basic Equipment
High quality laboratory consumables and disposables are provided by best-in-class companies with EU standards.
AHN
VWR
RITTER
SARSEDT
LABELIANS